Installing Honeywell Gas Detectors can differ in difficulty based upon the top you are mounting the gas detector on. Drop ceiling panels would be the easiest but you may also do the installation directly onto steel ducting, though this might necessitate a partial disassembly of the ductwork to achieve inside. Honeywell gas detectors are actually wireless so you don't have to string communication wires to the bottom station. As long as the detector port is pointed downwards, the gas detector could be mounted anywhere within transmitting selection of the bottom station (which depends upon the model you buy).
Place the gas detector flat from the wall, with the detector port pointed to the ground. You should use tape to temporarily contain the detector to the wall. Use wood screws to thread in the mounting holes after which drill to the wall. You will find only two attachment points on top left and bottom right corner. Screw before screw head is flush with the gas detector's flange after which take away the tape. Tape both metal attachment clamps that included the detector to the pole you wish to mount onto. Align the bolt holes. Then mount the gas detector (with the port point towards the floor) by threading bolts through the attachment point on the detector and the clamps. Screw the nuts onto the threaded end of the bolts manually, tightening with a hand wrench before clamps no more wiggle. Take away the tape from the clamps. Screw the L flange that included the detector to the ceiling panel with wood screws until it's flush with the flange. Then tape the detector to another the main L flange therefore the detector's gas port is pointing to the ground. Then thread bolts through the gas detector and the flange. Screw the nuts onto the bolts manually, utilizing a hand wrench at the conclusion, stopping when the detector no more wiggles on the flange. Take away the tape. Remove the vent panel or maintenance panel within in arms reach of where you wish to duct-mount the gas detector. Drill a hole in the duct work how big the detector gas port, the size depends upon which type of Honeywell detector you're using. The duct mount flange that accompany the detector mounts within the gas port with a company push. Mount the gas detector extension on the finish of the gas port with yet another firm push. Drill another hole how big the gas probe that's on the finish of the detector extension. Mount the duct work flange with the attached gas detector within the larger gas port hole, screwing to the duct use metal screws. Reach to the maintenance panel and by hand thread the gas probe extension through small probe hole you drilled.
没有评论:
发表评论